Standard Support Constructions In Accordance With DIN 4102 Part 12

Standard Support Constructions - Niedax | Kleinhuis | Fintech

The following standard support constructions are defined in the DIN 4102 Part 12 test standard:  
 

The verification of a cable system for circuit integrity maintenance in accordance with DIN 4102 Part 12, installed with a standard support construction consists of 2 documents: 

 

1. German classification report (abP), issued to the cable manufacturer. This contains a note on the test results relating to standard support constructions. 

2. expert judgement report issued to the manufacturer of the standard supporting structure. This statement contains a detailed description of the respective standard support construction with a list of the components to be used.  

One of the advantages of the standard support constructions is the uncomplicated combination of cable systems with cables from different manufacturers.

Taking into account a German classification report (AbP) for the cable system, all cables with circuit integrity maintenance that are approved for the respective design can be used - without further testing.  

Advantages of using standard support constructions

  • Free choice of cable  

  • No commitment to specific cable types and manufacturers  

  • Ideal for smaller projects  

  • Numerous installation variants 

 

If tests are carried out that deviate from the standard support construction, the test results only apply to the tested combination of cable and support structure. 

However, this does not only have advantages, as the limited load-bearing capacity and the construction method result in higher installation costs. For this reason, standard support constructions tend to be used for smaller projects.